What was found
INSPECTION TYPE: C, HORZ STAB NR 4 LT BARREL NUT HOLE FOUND CORRODED AT BOTTOM SIDEWALL AND BEARING SURFACE. CORROSION AT B/N HOLE NR 4 LT REMOVED, BLENDED AND REAMED TO 0.944 INCH, FOUND OUT OF LIMIT FAB SLEEVE AND BUSHING IAW EO MD11-5510-19409-H. APPLIED SEALANT PR1422B1/2 AT BLEND AREA AND INSTALLED SLEEVE BUSHING AT B/N HOLE NR 4 LT IAW EO MD11-5510-19409-H. REPAIR CUT OUT AT B/N HOLE NR 4 LT IAW EO MD 11-5510-19409-H AND EN:1296-04 FOUND WITHIN LIMIT AND SATISFACTORY.