What was found
INSPECTION TYPE:N/A ATB - HYD QTY AFTER TAKEOFF WENT TO 2.0 GALS AFTER FLAP RETRACTION QTY HELD STEADY AT 2.3 GALS. FOUND ASYS QTY LOW, SERVICED TO PROPER LEVEL PER M/M 12-12-00-2. CHECKED L/E SLAT ACTUATOR AND FLAP POW'S FOR LEAKS, NONE FOUND. NO OTHER LEAKS NOTED ON A/C. RAN ENGS & CYCLED FLAPS AND FLT CONTROLS HYD REMAINED THE SAME.