What was found
INSPECTION TYPE: C, BS 440 - 460 LBL 86 TIE DOWN TRACK I/B FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.044 X 1 X 3 INCH EXCEED SRM 53-10-01 FIG 1, LIMIT. TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 1A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, BS 440 - 460 LBL 86 TIE DOWN TRACK I/B FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.044 X 1 X 3 INCH EXCEED SRM 53-10-01 FIG 1, LIMIT. TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 1A.