What was found
INSPECTION TYPE: C, BS 1480 - 1500 RBL 34, TIE DOWN TRACK FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.040 X 1 X 2 INCH EXCEED SRM 53-10-01 FIG 1, LIMIT. TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 1A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, BS 1480 - 1500 RBL 34, TIE DOWN TRACK FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.040 X 1 X 2 INCH EXCEED SRM 53-10-01 FIG 1, LIMIT. TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 1A.