What was found
INSPECTION TYPE: C, BS 1700, RBL 11 - 33 FLOORBEAM FOUND CORRODED. CORROSION BLEND OUT 0.050 X 2 X 2 EXCEED SRM 53-10-01 FIG 1, LIMIT FLOORBEAM REPAIRED AS PER SRM 51-40-04 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, BS 1700, RBL 11 - 33 FLOORBEAM FOUND CORRODED. CORROSION BLEND OUT 0.050 X 2 X 2 EXCEED SRM 53-10-01 FIG 1, LIMIT FLOORBEAM REPAIRED AS PER SRM 51-40-04 FIG 1.