What was found
INSPECTION TYPE: C, TIE DOWN TRACK / BS 1000 B/H VERTICAL SUPPORT FTG CRACKED AT LBL 33 (CRACK LENGTH 1 INCH). M/DECK TIE DOWN TRACK BS 1000 B/H VERTICAL SUPPORT FTG REPLACED AT LBL 33 AREA AS PER SRM 51-10-01 PG 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, TIE DOWN TRACK / BS 1000 B/H VERTICAL SUPPORT FTG CRACKED AT LBL 33 (CRACK LENGTH 1 INCH). M/DECK TIE DOWN TRACK BS 1000 B/H VERTICAL SUPPORT FTG REPLACED AT LBL 33 AREA AS PER SRM 51-10-01 PG 9.