What was found
INSPECTION TYPE: C, BS 480-510 LBL 66 TIE DOWN TRACK I/B FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.041 X 1 X 3 EXCEED SRM 53-10-01 FIG 1, LIMIT TIE DOWN TRACK REPLACED AS PER SRM 51-10-01 PG 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, BS 480-510 LBL 66 TIE DOWN TRACK I/B FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.041 X 1 X 3 EXCEED SRM 53-10-01 FIG 1, LIMIT TIE DOWN TRACK REPLACED AS PER SRM 51-10-01 PG 9.