What was found
INSPECTION TYPE:C M/D- BS 480-500 LBL 68 TIE DOWN TRACK O/B FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.039 X 1 X 2 EXCEED SRM 53-10-01 FIG 1, LIMIT TIE DOWN TRACK REPLACED AS PER SRM 51-10-01 PG 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D- BS 480-500 LBL 68 TIE DOWN TRACK O/B FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.039 X 1 X 2 EXCEED SRM 53-10-01 FIG 1, LIMIT TIE DOWN TRACK REPLACED AS PER SRM 51-10-01 PG 9.