What was found
INSPECTION TYPE:C M/D-BS 1650 LBL 118 FLOOR SUPPORT FOUND CORRODED. CORROSION BLEND OUT 0.035 X 1 X 1 INCH EXCEED SRM 53-10-01 FIG 1 LIMIT. FLOOR SUPPORT REPAIRED AS PER SRM 51-40-03 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D-BS 1650 LBL 118 FLOOR SUPPORT FOUND CORRODED. CORROSION BLEND OUT 0.035 X 1 X 1 INCH EXCEED SRM 53-10-01 FIG 1 LIMIT. FLOOR SUPPORT REPAIRED AS PER SRM 51-40-03 FIG 1.