What was found
RT WING L/E CAVITY AT FSSI 998 L/E MOST FWD D-SECTION ATT PANEL AND UPPER EDGE CHORD FOUND CRACKED, AFT OF NR 20 VC FLAP, CRACK LENGTH 1 INCH. PANELS AND CHORD REPAIRED AS PER SRM 57-20-03 FIG 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT WING L/E CAVITY AT FSSI 998 L/E MOST FWD D-SECTION ATT PANEL AND UPPER EDGE CHORD FOUND CRACKED, AFT OF NR 20 VC FLAP, CRACK LENGTH 1 INCH. PANELS AND CHORD REPAIRED AS PER SRM 57-20-03 FIG 7.