What was found
M/DECK BS 1940 AND 1960 LBL 80 INCH TIE DOWN FTG ATT PLATE FOUND CORRODED. CORROSION BLEND OUT 0.020 INCH BY 1 INCH BY 1 INCH EXCEED SRM 53-10-01 FIG 1 LIMIT, M/D BS 1940 LBL 80 INCH TIE DOWN FTG REPLACED AS PER MM 20-51-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
M/DECK BS 1940 AND 1960 LBL 80 INCH TIE DOWN FTG ATT PLATE FOUND CORRODED. CORROSION BLEND OUT 0.020 INCH BY 1 INCH BY 1 INCH EXCEED SRM 53-10-01 FIG 1 LIMIT, M/D BS 1940 LBL 80 INCH TIE DOWN FTG REPLACED AS PER MM 20-51-01.