What was found
BS 1265 STR -26R FRAME BELOW DOOR LOWER SILL FASTENER HOLE FOUND CRACKED AT FRAME WEB RUNNING I/B AND O/B (CRACK LENGTH 1/16 INCH), BS 1265 RT FRAME WEB INTERIM REPAIRED AS PER DWG 624U0060.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1265 STR -26R FRAME BELOW DOOR LOWER SILL FASTENER HOLE FOUND CRACKED AT FRAME WEB RUNNING I/B AND O/B (CRACK LENGTH 1/16 INCH), BS 1265 RT FRAME WEB INTERIM REPAIRED AS PER DWG 624U0060.