What was found
INSP TYPE: C, M/D - BS 460 RT FLOORBEAM WEB FOUND CRACKED AT STR 13R RBL 98 AREA, (CRACK LENGTH 0.3750 IN). FLOORBEAM WEB REPAIRED AS PER SRM 53-10-07 FIG 11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSP TYPE: C, M/D - BS 460 RT FLOORBEAM WEB FOUND CRACKED AT STR 13R RBL 98 AREA, (CRACK LENGTH 0.3750 IN). FLOORBEAM WEB REPAIRED AS PER SRM 53-10-07 FIG 11.