What was found
BS 1170 LBL 11- RBL 11 FLOOR SUPPORT CORROSION. CORROSION BLEND OUT 0.036 BY 1.215 BY 1.5 IN. EXCEED SRM 53-10-01 FIG 1 LIMITS. M/D - BS 1170 LBL 11 - RBL 11 FLOOR SUPPORT REPLACED AS PER SRM 51-10-01 PG 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1170 LBL 11- RBL 11 FLOOR SUPPORT CORROSION. CORROSION BLEND OUT 0.036 BY 1.215 BY 1.5 IN. EXCEED SRM 53-10-01 FIG 1 LIMITS. M/D - BS 1170 LBL 11 - RBL 11 FLOOR SUPPORT REPLACED AS PER SRM 51-10-01 PG 9.