What was found
BS 550- 570 LBL 32 TIE DOWN TRACK FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.048 BY 0.4375 BY 1.0 IN. EXCEED SRM 53-10-01 FIG 1 LIMITS, TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 1A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 550- 570 LBL 32 TIE DOWN TRACK FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.048 BY 0.4375 BY 1.0 IN. EXCEED SRM 53-10-01 FIG 1 LIMITS, TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 1A.