What was found
INSPECTION TYPE:C M/D- BS 760-780 RBL 75 TIE DOWN TRACK FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.029 X .5 X 4 INCH EXCEED SRM 53-10-01 FIG 1 LIMITS. M/D BS 750-870 RBL 75 TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 1A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D- BS 760-780 RBL 75 TIE DOWN TRACK FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.029 X .5 X 4 INCH EXCEED SRM 53-10-01 FIG 1 LIMITS. M/D BS 750-870 RBL 75 TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 1A.