What was found
BS 760 LBL 65 FLOORBEAM FOUND CORRODED. CORROSION BLEND OUT 0.055 BY 0.5 BY 2.5 IN. EXCEED SRM 53-10-01 FIG 1 LIMITS. FLOORBEAM REPAIRED AS PER SRM 51-40-04 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 760 LBL 65 FLOORBEAM FOUND CORRODED. CORROSION BLEND OUT 0.055 BY 0.5 BY 2.5 IN. EXCEED SRM 53-10-01 FIG 1 LIMITS. FLOORBEAM REPAIRED AS PER SRM 51-40-04 FIG 1.