What was found
AFT CARGO BAY BS 1800 BL 0 AND FLOORBEAM UPPER FLANGE CRACKED. CRACK LENGTH 2.5 IN. AFT CARGO BAY BS 1800 LBL 22 TO RBL 40 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 51-40-04 FIG 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO BAY BS 1800 BL 0 AND FLOORBEAM UPPER FLANGE CRACKED. CRACK LENGTH 2.5 IN. AFT CARGO BAY BS 1800 LBL 22 TO RBL 40 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 51-40-04 FIG 2.