What was found
INSPECTION TYPE:C. U/D, BS 400, RBL 0-6 FLOORBEAM UPPER CHORD FOUND SLIGHTLY CORRODED. CORROSION BLEND OUT 0.040 BY 0.875 BY 1.5 IN. EXCEED SRM 53-10-01 FIG 1 LIMITS, FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 51-40-04 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C. U/D, BS 400, RBL 0-6 FLOORBEAM UPPER CHORD FOUND SLIGHTLY CORRODED. CORROSION BLEND OUT 0.040 BY 0.875 BY 1.5 IN. EXCEED SRM 53-10-01 FIG 1 LIMITS, FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 51-40-04 FIG 1.