What was found
U/D BS 400-402 RBL 76 LONGITUDINAL FLOOR SUPPORT FOUND CRACKED, CRACK LENGTH 2". U/D BS 400-402 RBL 76 LONGITUDINAL FLOOR SUPPORT REPAIRED AS PER SRM 51-40-04 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
U/D BS 400-402 RBL 76 LONGITUDINAL FLOOR SUPPORT FOUND CRACKED, CRACK LENGTH 2". U/D BS 400-402 RBL 76 LONGITUDINAL FLOOR SUPPORT REPAIRED AS PER SRM 51-40-04 FIG 1.