What was found
BS 360 FLOORBEAM UPPER STRUCTURE HORIZONTAL AFT FLANGE 1EA MOUNTING HOLE CRACK, CRACK LENGTH .125. BS 360 RBL 45 AFTER FLANGE OF FLOORBEAM UPPER STRUCTURE REPAIRED AS PER UPS EO NR B747-5320-12407 APPENDIX 'D' PLAN C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 360 FLOORBEAM UPPER STRUCTURE HORIZONTAL AFT FLANGE 1EA MOUNTING HOLE CRACK, CRACK LENGTH .125. BS 360 RBL 45 AFTER FLANGE OF FLOORBEAM UPPER STRUCTURE REPAIRED AS PER UPS EO NR B747-5320-12407 APPENDIX 'D' PLAN C.