What was found
INSPECTION TYPE:C1 CRACKED FLOORBEAM FITTING AT A-PIT DOOR JAMB AT FS 340. REMOVED CRACKED FLOORBEAM FITTING, FABRICATED REPLACEMENT IAW DWG 975 4022, AND INSTALLED IAW DC-8 SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1 CRACKED FLOORBEAM FITTING AT A-PIT DOOR JAMB AT FS 340. REMOVED CRACKED FLOORBEAM FITTING, FABRICATED REPLACEMENT IAW DWG 975 4022, AND INSTALLED IAW DC-8 SRM 51-1-20D.