What was found
INSPECTION TYPE:C1 B-PIT BETWEEN STA 480-460 L31L SPLICE FITTING CRACKED. REMOVED CRACKED SPLICE FITTING, FABRICATED REPLACEMENT FITTING IAW DWG 3750257, AND INSTALLED IAW DC-8 SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1 B-PIT BETWEEN STA 480-460 L31L SPLICE FITTING CRACKED. REMOVED CRACKED SPLICE FITTING, FABRICATED REPLACEMENT FITTING IAW DWG 3750257, AND INSTALLED IAW DC-8 SRM 51-1-20D.