What was found
INSPECTION TYPE:C-3. D PIT DOOR CUTOUT AFT SIDE CHAFED AND FASTENER HAS SHORT E.D. AT STA 1440. REMOVED FASTENER AND CUT OUT DAMAGED AREA AND INSTALLED DOUBLER, TRIP AND 2 FILLERS IAW EO DC8 5330-22423-A AND SAASK 840-807058.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C-3. D PIT DOOR CUTOUT AFT SIDE CHAFED AND FASTENER HAS SHORT E.D. AT STA 1440. REMOVED FASTENER AND CUT OUT DAMAGED AREA AND INSTALLED DOUBLER, TRIP AND 2 FILLERS IAW EO DC8 5330-22423-A AND SAASK 840-807058.