What was found
INSPECTION TYPE:C1 FOUND EXFOLIATION CORROSION AND CRACKS ON COCK PIT SUBFLOOR AT STA -67 RBL 60 INSIDE RIGHT NOSE TUNNEL. CUT OUT DAMAGED AREA, FABRICATED, AND INSTALLED REPAIR IAW DWG SRO8530 026 AND DC-8 SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1 FOUND EXFOLIATION CORROSION AND CRACKS ON COCK PIT SUBFLOOR AT STA -67 RBL 60 INSIDE RIGHT NOSE TUNNEL. CUT OUT DAMAGED AREA, FABRICATED, AND INSTALLED REPAIR IAW DWG SRO8530 026 AND DC-8 SRM 51-1-20D.