What was found
INSPECTION TYPE:C3 "B" PIT DOOR TORQUE JAMB FROM FS 520-560 HAS CORROSION AROUND NUT PLATES. REMOVED CORROSION AROUND NUT PLATES AND FOUND IN LIMITS. FOUND CORROSION ON FRAME AT FS 540 L36. CORROSION FOUND OUT OF LIMITS, CUT OUT DAMAGE, FABRICATED, AND INSTALLED REPAIR IAW DWG DC8-53A-011.