What was found
FOUND C-PIT INTERCOSTAL END FITTING AT FS 1140 AT LONGERON 35L CRACKED AT UP PER FASTENER ATTACH POINT. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FITTING IAW DWG 3758496 9 AND DC-8 SRM 51-1-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND C-PIT INTERCOSTAL END FITTING AT FS 1140 AT LONGERON 35L CRACKED AT UP PER FASTENER ATTACH POINT. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FITTING IAW DWG 3758496 9 AND DC-8 SRM 51-1-21.