What was found
NR 16 LEADING EDGE SLAT TRACK INBOARD FITTING FOUND WITH SIGN OF CRACK AS MARKED. HFEC C/O IAW DAC NDT SPM R.11 PART 06-10-01.001 AND CRACK CONFIRM APPROX 1/2 INCH LONG. LT NR 16 L/E SLAT TRACK AND DOOR REMOVED PER 57-40-01 REV 47 CRACKED. RIB REMOVED PER SRM 51-35-01 AND 51-33-01 V.2R.35. NEW RIB HOLES TRANSFER PER SRM 51-31-01V.2R.35 AND DWG ARB2873. NEW RIB INSTALLED PER SRM 51-35-0 1 AND 51-33-01 V.2R.35. LHW NR 16 SLAT TRACK AND DOOR REINSTALLED PER 57-40-01R.45.