What was found
INSPECTION TYPE: C, NR 1 LT CORROSION ON WALL BASE & BEARING SURFACE OF BARREL NUT HOLE. CORROSION AT BEARING S/W REMOVED PER SRM 51-21-01V.2R.35, FOUND OUT OF LIMIT PER EO MD11-5510-14909-I. REWORKED BARREL NUT HOLE NR 1 LT PER SRM 51-21-01 V.2.R35. FAB REPAIR SLEEVE BUSHING PER EO MD11-5510-19409-I. APPLIED SEALANT PR1422B1/2 AT NR 1 LT BARREL NUT HOLE & INSTALLED FAB BUSHING PER EO MD11- 5510-14909-I. REPAIR COMPLETED AT BARREL NUT HOLE NR 1 LT FOUND IAW EN 1116-05.