What was found
INSPECTION TYPE:C NR 10 LT CORROSION ON WALL, BASE & BEARING SURFACE OF BARREL NUT HOLE. CORROSION REMOVED AT BARREL NUT HOLE NR 10 LT PER SRM 51-21-01V.2.R.35, FOUND OUT OF LIMIT. REWORKED BARREL NUT HOLE 10 LT PER SRM 51-21-01V.2R.35. FAB SLEEVE BUSHING PER EO MD11-5510-19409-I. APPLIED SEALANT PR1422B1/2 AT BARREL NUT HOLE NR 10 LT & INSTALLED SLEEVE BUSHING PER MD11-5510-19409-I. REPAIR COMPLETED AT BARREL NUT HOLE NR 10 LT FOUND PER EN1122-05 & WITHIN LIMIT.