What was found
INSPECTION TYPE:C NR 30 LT CORROSION ON WALL, BASE & BEARING SURFACE OF BARREL NUT HOLE. CORROSION REMOVED ON BARREL NUT HOLE NR 30 LT PER SRM 51-21-01.V2.R.35, FOUND OUT OF LIMIT. REWORKED BARREL NUT HOLE NR 30 LT PER SRM 51-21-01.V2.R.35. FAB SLEEVE BUSHING PER EO MD11-5510-19409-I. APPLIED SEALANT PR1422B1/2OB BARREL NUT HOLE NR 30 LT & INSTALLED FAB SLEEVE BUSHING PER EO MD11-5510-19409-I. REPAIR COMPLETED AT BARREL NUT HOLE NR 30 LT PER EN1138-05 FOUND WITHIN LIMIT & SATISFACTORY.