What was found
INSPECTION TYPE:C NR 19 LT CORROSION ON WALL, BASE & BEARING SURFACE OF BARREL NUT HOLE. CORROSION REMOVED ON BARREL NUT HOLE NR 19 LT PER SRM 51-21-01.V2.R36, FOUND OUT OF LIMIT. REWORKED BARREL NUT HOLE NR 19 LT PER EN1128-05. FAB SLEEVE BUSHING PER EO MD11-5510-19409-I. APPLIED SEALANT PR1422B1/2 ON BARREL NUT HOLE NR 19 LT & INSTALLED FAB SLEEVE BUSHING PER EO MD11-5510-19409-I. REPAIR COMPLETED ON BARREL NUT HOLE NR 19 LT PER EN1128-05, FOUND WITHIN LIMIT & SATISFACTORY.