What was found
INSPECTION TYPE: C-CK, CORROSION ON SEAT TRACK AT STA 806-910 X=-75. REMOVED CABIN CORROSION ON SEAT TRACK AT STA 806-910 X=-75 AND FOUND EXCEED LIMIT AS PER SRM 53-70-00 FIG 3 VOL I REV 37. MANILFOLD FAILURE SENSING ELEMENT IN THE VICINITY OF CORRODED SEAT TRACK REMOVED AS PER AMM 36-23-07 REV 52 FOR SM ACCESS. CARRY OUT HFEC IAW DAC NDT SPM REV1 2, FABRICATED SPLICE PLATE AS PER SRM 53-70-00 FIG 1 VOL 1 REV 37.