What was found
INSPECTION TYPE:C-CHECK CENTER CARGO RT TUNNEL AT STA 5-123 LONGERON 33RT SPLICE FOUND WITH CORROSION AS MARKED. CORROSION REMOVED AND TREATED AS PER SRM 51-21-01 VOL II REV 37 FOUND WITHIN LIMIT AS PER SRM 53-00-01 VOL I REV 37.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C-CHECK CENTER CARGO RT TUNNEL AT STA 5-123 LONGERON 33RT SPLICE FOUND WITH CORROSION AS MARKED. CORROSION REMOVED AND TREATED AS PER SRM 51-21-01 VOL II REV 37 FOUND WITHIN LIMIT AS PER SRM 53-00-01 VOL I REV 37.