What was found
INSPECTION TYPE:C, CABIN ANGLE FITTING BETWEEN STA 1239-1256 LONGERON 27 RT FOUND CORRODED. CORROSION REMOVED AT CABIN AREA STA 1239 TO 1256, FOUND OUT OF LIMIT. ORIG THK 0.238" & MAT REMOVED IS 0.090" PER SRM 53-00-01 F3.V1 R.37. ANGLE FITTING BRACKET REMOVED & FAB LONGERON AEA7533-2 PER EN1419-05 & DOUGLAS DWG AEA7533. NEW FAB LONGERON PICK UP HOLE PER SRM 51-31-01V.2.R37. INSTALLATION NEW FAB LONGERON CUTOUT PER 51-33-01.V2.R37-SATIS.