As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C AND IS SUSPECT SKIN CRACK AT FASTENER HOLE SECTION 41 RT AT BS 239 S15R. PL S. CARRY OUT NDI AND RECTIFY IF NECESSARY IAW SRM HFEC INSP. CARRIED OUT IAW NDTM PT 6 51-00-00. CRACK CONFIRMED AND ENDS MARKED. REPAIR CARRIED OUT IAW SRM 53-30-03, 51-10-2