What was found
INSPECTION TYPE:C SUSPECT SKIN CRACK AT UPPER VHF ANTENNA CUT OUT AFT EDGE. HFEC INSPECTION CARRIED OUT ON THE ABOVE AREA IAW B727-NDTM PT 6 51-1 00-00 FIG 4. REMOVED ANTENNA IAW SRM 51-30-02. CUTOUT CARRIED OUT IAW EQR 2006024-6. HFEC CARRIED OUT ON FASTENER HOLES COMMON TO REPAIR IAW B727-NDTM PT6 51-00-00 FIG 4. FABRICATED REPAIR PARTS IAW AAAE EO 20060 24-003. REPROTECTED AREA IAW SRM 51-10-02.