What was found
INSPECTION TYPE:SV SHEAR TIE CRACKED AT STA 441 STR 26L. REMOVED CRACKED SHEAR TIE AT STA 441 STR 26L IAW SRM 51-30-02, FABRICATED AND INSTALLED SHEAR TIE AT STA 441 STR 26L IAW DWG 6913293 AND SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SV SHEAR TIE CRACKED AT STA 441 STR 26L. REMOVED CRACKED SHEAR TIE AT STA 441 STR 26L IAW SRM 51-30-02, FABRICATED AND INSTALLED SHEAR TIE AT STA 441 STR 26L IAW DWG 6913293 AND SRM 51-30-02.