What was found
BS 2300 RBL 60" FLOOR SUPPORT FOUND CORROSION. CORROSION BLEND OUT 0.034" BY 1" BY 1" EXCEED SRM 53-10-01 FIG 1 LIMITS, M/D BS 2300 TO BS 2320 RBL 60" FLOOR SUPPORT REPLACED IAW SRM 51-10-01 PAGE 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 2300 RBL 60" FLOOR SUPPORT FOUND CORROSION. CORROSION BLEND OUT 0.034" BY 1" BY 1" EXCEED SRM 53-10-01 FIG 1 LIMITS, M/D BS 2300 TO BS 2320 RBL 60" FLOOR SUPPORT REPLACED IAW SRM 51-10-01 PAGE 9.