What was found
INSPECTION TYPE:C NR 1 PYLON NAC STA236 I/B VERTICAL FRAME BOTTOM CRACKED, CRACK LENGTH 2.75". VERTICAL FRAME REPLACED AS PER SRM51-10-01 P.9 AND INSTALLED AS PER SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C NR 1 PYLON NAC STA236 I/B VERTICAL FRAME BOTTOM CRACKED, CRACK LENGTH 2.75". VERTICAL FRAME REPLACED AS PER SRM51-10-01 P.9 AND INSTALLED AS PER SRM 51-30-02.