What was found
INSPECTION TYPE:C NWW - LT SIDEWALL PANEL BS 300-320 WL 180 STIFFENER RADIUS FOUND CRACK APPROX .5 INCH IN LENGTH. STIFFENER REPLACED & INSTALLED AS PER SRM 51-10-01 PG 9 & 51-30-02 AT NWW LT SIDEWALL PANEL BS 300-320 WL 180 AREA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C NWW - LT SIDEWALL PANEL BS 300-320 WL 180 STIFFENER RADIUS FOUND CRACK APPROX .5 INCH IN LENGTH. STIFFENER REPLACED & INSTALLED AS PER SRM 51-10-01 PG 9 & 51-30-02 AT NWW LT SIDEWALL PANEL BS 300-320 WL 180 AREA.