As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C NWW - RIGHT SIDEWALL PANEL BS 265-280 WL 180 STIFFENER RADIUS FOUND CRACK APPROX .25 INCH LONG. STIFFENER REPLACED & INSTALLED AS PER SRM 51-10-01 PG 9 & 51-30-02 AT BS 265-280 WL 180 AREA OF NWW RIGHT SIDEWALL PANEL.