What was found
FLOOR FTG ATT FLOOR SUPPORT PLATE AT BS 1780 RBL60 FOUND CORROSION. CORROSION BLEND OUT 0.024" BY 1.5" BY 1.5" EXCEED SRM LIMIT. TIE DOWN FITTING REPLACED AS PER MM 53-42-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR FTG ATT FLOOR SUPPORT PLATE AT BS 1780 RBL60 FOUND CORROSION. CORROSION BLEND OUT 0.024" BY 1.5" BY 1.5" EXCEED SRM LIMIT. TIE DOWN FITTING REPLACED AS PER MM 53-42-00.