What was found
BS 1680 LBL36 TIE DOWN FTG FWD FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.026" BY 0.5" BY 1" EXCEED SRM LIMIT. TIE DOWN FTG PLATE REPLACED AS PER MM 53-42-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1680 LBL36 TIE DOWN FTG FWD FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.026" BY 0.5" BY 1" EXCEED SRM LIMIT. TIE DOWN FTG PLATE REPLACED AS PER MM 53-42-00.