What was found
BS 1170 LBL11 TO RBL11 LATERAL FLOORBEAM FOUND CORRODED. CORROSION BLEND OUT 0.042" BY 3/4" BY 2" EXCEED SRM LIMIT. BS 1170 LBL 11 TO RBL 11 FLOORBEAM REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1170 LBL11 TO RBL11 LATERAL FLOORBEAM FOUND CORRODED. CORROSION BLEND OUT 0.042" BY 3/4" BY 2" EXCEED SRM LIMIT. BS 1170 LBL 11 TO RBL 11 FLOORBEAM REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.