What was found
BS 1640-1660 RBL 11 TIE DOWN TRACK I/B FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.024" BY 3/4" BY 1.5" EXCEED SRM LIMIT. BS 1620 TO BS 1750 RBL 11 TRACK REPAIRED AS PER SRM 53-10-05 FIG14 REFER NRC5933 FOR WORKING DETAIL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1640-1660 RBL 11 TIE DOWN TRACK I/B FLANGE FOUND CORRODED. CORROSION BLEND OUT 0.024" BY 3/4" BY 1.5" EXCEED SRM LIMIT. BS 1620 TO BS 1750 RBL 11 TRACK REPAIRED AS PER SRM 53-10-05 FIG14 REFER NRC5933 FOR WORKING DETAIL.