What was found
RT BS 340 UPPER DECK FLOORBEAM AT FRAME CONNECTION FOUND 1 HOLE CRACK AT FRAME, CRACK LENGTH 1/16". UPPER DECK BS 340 FLOORBEAM ATTACHED FRAME REPAIRED AS PER HX RS# R53-12-35437 AT BETWEEN STR 10AR TO STR 13AR AREA UPON THE ACCUMULATION OF 10000 FLT CYC. PERFORM A DETAIL VISUAL INSP OF THE FWD AND AFT SIDES OF THE FRAME IN THE REPAIR AREA IS REQ THAT IS TO REPEAT EVERY 3000 CYC REF UPS EO NR B747-5310-24059-A.