What was found
INSPECTION TYPE:C M/D - BS 440-460 LBL 11 TIE DOWN TRACK I/B FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.057" X .5" X 1.5" EXCEED SRM LIMIT. M/D BS 440-460 LBL 11 TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 17.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D - BS 440-460 LBL 11 TIE DOWN TRACK I/B FLANGE FOUND CORROSION. CORROSION BLEND OUT 0.057" X .5" X 1.5" EXCEED SRM LIMIT. M/D BS 440-460 LBL 11 TIE DOWN TRACK REPAIRED AS PER SRM 53-10-05 FIG 17.