What was found
INSPECTION TYPE:C M/D TIE DOWN TRACK BS 480-510 LBL 33 CORRODED. CORROSION BLEND OUT 0.042 X .75 X 3 INCH EXCEED SRM LIMIT. CABIN BS 460 TO BS 510 LBL 33 TRACK REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D TIE DOWN TRACK BS 480-510 LBL 33 CORRODED. CORROSION BLEND OUT 0.042 X .75 X 3 INCH EXCEED SRM LIMIT. CABIN BS 460 TO BS 510 LBL 33 TRACK REPLACED AND INSTALLED AS PER SRM 51-10-01 PG 9 AND 51-30-02.