What was found
INSPECTION TYPE:C M/D BS 240-260 RBL 72 FLOOR SUPPORT CORROSION. CORROSION BLEND OUT 0.028" X .5" X 1" EXCEED SRM 53-10-01 FIG 1 LIMITS. M/D BS 220 TO BS 300 RT FLOOR SUPPORT REPLACED & INSTALLED AS PER SRM 51-10-01 PG 9 & 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C M/D BS 240-260 RBL 72 FLOOR SUPPORT CORROSION. CORROSION BLEND OUT 0.028" X .5" X 1" EXCEED SRM 53-10-01 FIG 1 LIMITS. M/D BS 220 TO BS 300 RT FLOOR SUPPORT REPLACED & INSTALLED AS PER SRM 51-10-01 PG 9 & 51-30-02.